Drawing Analysis (bakery Tenant Improvement)

 The drawing file you provided is a full architectural and interior design permit submittal set for Paris Baguette in North Hollywood (NOHO). Here's an analysis of the key elements:


๐Ÿ”ง Project Overview

  • Project Name: Paris Baguette Tenant Improvement Project

  • Location: 6160 N Laurel Canyon Blvd, Suite 105, Los Angeles, CA 91606

  • Architect: AHK|Architecture, Sylmar, California

  • Permit Set Date: 9/30/2025


๐Ÿ“ Plans Included

  • Existing Plan

  • Proposed Occupancy Plan

  • Equipment Plan

  • Kitchen Equipment Plan

  • Reflected Ceiling Plan

  • Roof Plan

  • Interior Elevations

  • Finish Schedule

  • Waterproofing and Construction Details


๐Ÿงฑ Room & Area Breakdown

SpaceArea (SF)Load FactorOccupancy
Seating Area3281/1522
Display Area4761/608
Kitchen7061/2003.5
Service Area2551/2001.3
Walk-in Cooler/Freezer (WIC/WIF)2481/3001
Hallway65--
Restroom144--

Total estimated occupant load: ~36.8 → rounded to 37


๐Ÿ› ️ Construction & Wall Types

  • Interior walls: 3 5/8" or 6" metal studs @16" O.C., 1 layer of GWB per side

  • Furring walls with 2.5", 3 5/8", and 6" metal studs

  • Low walls to 36", 40", or 48" A.F.F.

  • Walls extend 6" above ceiling and are braced to structure

  • New ADA-compliant fixtures, including knee and toe clearance details


ADA Compliance

  • 1 accessible seat provided (min. required)

  • ADA lavatory and knee/toe clearance diagrams included


๐Ÿงฏ Materials & Finishes

  • Flooring: Concrete with sealer; quarry tile (Ashen Gray); porcelain (cool piazza)

  • Walls: Paint (SW Promar 200, BM Ultra Spec), FRP panels, glazed ceramic tile

  • Ceilings: Acoustic ceiling tiles, gypsum board soffits

  • Baseboards: Metal (blackened steel), ceramic cove base (Daltile)


⚙️ Equipment Highlights

  • Deck ovens (x3), U-ovens (x2), fryers, mixers (KSM8990), slicers, Turbo Air units

  • Detailed fixture schedule with lighting: LED track, downlights, hood lights

  • Mop sink and water heater area detailed with waterproofing membrane info


⚠️ Notable Code References

  • Accessibility clearances and fixture mounting follow CBC Section 404.2.4.1 (A)

  • Flame spread limits per CBC Table 803.11

  • LRV (light reflectance value) for food prep and restroom areas ≥70%